Characteristics
- digital thermostat with 6 functions and built-in time switch clock with
day, week and year program. You can also limit temperature functions
and courses this way in real time.
- the temperature pro le can be changed using the time program
- complex home and water heating, solar heating, etc.
- two thermostats in one, two temperature inputs, two outputs with dry
contact
- maximum universal and variable thermostat including all ordinary
thermostat functions
- functions: two independent thermostats, dependent thermostat,
di erential thermostat, two level thermostat, zone-based thermostat,
dead zone thermostat
- monitoring function for short circuit or sensor disconnection
- program setting of output functions, calibration of sensors according
to reference temperature (o set)
- the thermostat is subject to the digital clock programs
- wide range for setting control temperature - 40 to 110°C
- clear display of set and measured data on a backlit LCD
- Switching modes:
- Auto – automatic switching mode:
- Programme
– switching based on a programme (astro or time).
- Random
– switches randomly in a 10–120 minute interval.
- Holiday
– holiday mode – option of setting up a period for
which the timer will be blocked, i.e. will not switch based on the
set programmes.
- Manual
– manual mode – option of controlling the individual
output relays manually
- Options of the automatic switching programme:
- ter - switches according to set thermostat function
(switches based on temperature sensors and associated
function)
- time program - switches or sets required temperature according
to set time program
- 100 memory locations for time programs (common for both
channels).
- Programming can be performed under voltage and in backup mode.
- The relay outputs do not work in backup mode (battery-powered)
- Choice of menu display - CZ / SK / EN / RO / PL / HU / RU (factory
setting EN).
- Choice of automatic daylight savings time transition according to
time zone.
- Backlit LCD display.
- Easy and quick setting with the help of 4 control buttons.
- Pluggable transparent cover on front panel.
- The time switch clock has a battery backup, which retains data in
case of a power outage (reserve backup time - up to 3 years).
- Power supply: AC 230V or 24V AC/DC (based on type of device).
- 2-module, DIN rail mounted

Table of Contents

Other manuals for Elko TER-9

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Elko TER-9 and is the answer not in the manual?

Elko TER-9 Specifications

General IconGeneral
BrandElko
ModelTER-9
CategoryThermostat
LanguageEnglish

Related product manuals