4.9  Condenser high temperature (Ht) alarms
Condenser high temperature
(Ht) alarms alert to problems
with the refrigeration system
such as a blocked condenser or
faulty condenser fan.
Follow the chart to troubleshoot
condenser high temperature (Ht)
alarms.
Yes
Iscondenser
sensorshort
circuit?
Replace
sensor
No
Ensurecondenserarea
freefromobstruction
Resetalarmpress
Downbuttononthe
controlleronce
HasHtalarm
cleared?
Yes
Isthecondenser
fanrunningwiththe
compressor?
Yes
IstheHtvalue
settocorrectvalue
forcooler?
Yes Faultcleared
No
Waituntilthe
temperaturehas
droppedbelowtheHt
value
No
Investigate
fan
problem
No
Manually
setHtto
thecorrect
value
Resetalarmpress
Downbuttononthe
controlleronce
HasHtalarm
cleared?
No
Replace
controller