4.4  Not cooling problems
Follow the chart below to troubleshoot problems of the cooler not cooling properly leaving the cooler
cabinet or product warm.
Coolerorproductis
warm
Checkcoolerwiring
andfuses
Iscontrolleron?
Ispower
availableatthe
controllermain
connector?
Replace
controller
Isthe
compressorLED
on?
Iscompressor
running?
Refrigeration
systemfault
Iscontroller
indicatingafault?
Power
availableat
controller
compressor
connector?
SeeAlarms
Isthecontroller
indefrost
(dEFdisplayed)?
Compressor
fault
No
No
Yes
YesYes
Yes
No
Yes
No
No
Yes
No
No
Replace
controller