7.4- PAR: Used to modify all the parameters of the control unit, press the UP button until PAR appears on the display, conrm with the OK button to
display the list of parameters, the display will show P01 (parameter number 1), the UP or DOWN button lets you scroll through the list of parameters (see
parameter table)
Parameter
number Description Settable values Default value
Modified
value
P01 Enables automatic closing ON/OFF ON
P02 Sets the automatic closing time 0-600 seconds 60 seconds
P03 AP/CH input operation 1= when opening, AP/CH input not active
(condo)
2=AP/CH as sequential (open, stop, close, stop..)
3=AP/CH as sequential (open, open, close..)
1
P04 Pre-flash ON/OFF ON
P05 Closing after photocell disengagement ON/OFF OFF
P06 Type of safety device connected to the
STPA input
1= photocell as protection on opening
(if engaged it stops the gate, until it is disengaged, and then it continues
opening)
2= microswitch sensitive edge
3= resistive sensitive edge (balanced with resistance (8.2Kohm)
1
P07 AUX output operating mode ON = slow flash during opening, steady with gate open, fast flash dur-
ing closing
OFF = on steady while moving and with gate open, and off when the
gate is closed
ON
P08 Enables photocell control OFF= Control disabled, 1= Control on PHOTO input
2= Control on STPA input, 3= Control on STPA and PHOTO inputs
OFF
P09
Slowdown distance when closing M1 From 0 to 100% of travel 30%
P10
Slowdown distance when closing M2 From 0 to 100% of travel 30%
P11
Slowdown distance when opening M1 From 0 to 100% of travel 70%
P12
Slowdown distance when opening M2 From 0 to 100% of travel 70%
P13
Opening speed M1 From 50 to 100% 100%
P14
Opening speed M2 From 50 to 100% 100%
P15
Closing speed M1 From 50 to 100% 100%
P16 Closing speed M2
From 50 to 100% 100%
P17
Opening deceleration speed M1
(15-75 with encoder), (35-70 without encoder) 50%
P18
Opening deceleration speed M2
(15-75 with encoder), (35-70 without encoder) 50%
P19
Closing deceleration speed M1
(15-75 with encoder), (35-70 without encoder) 50%
P20
Closing deceleration speed M2
(15-75 with encoder), (35-70 without encoder) 50%
P21
Motor M1 force From 1 minimum to 10 maximum 5
P22
Motor M2 force From 1 minimum to 10 maximum 5
P23
Acceleration on starting M1 1-5 ( 1=maximum acceleration 5= minimum acceleration) 3
P24
Acceleration on starting M2 1-5 ( 1=maximum acceleration 5= minimum acceleration)
3
P25
Deceleration on slowing down M1 1-8 ( 8= maximum deceleration 1= minimum deceleration)
6
P26
Deceleration on slowing down M2 1-8 ( 8= maximum deceleration 1= minimum deceleration)
6
P27
-
P28
-
Parameter table