33
VIMAR group
Parameter number Description Settable values Default value Modified value
P29 Offset for opening From 0 to 60 seconds
3 seconds
P30 Offset for closing From 0 to 60 seconds 6 seconds
P31 Motors present 1 motor or 2 motors 2
P32
Hammering and electric hook recon-
nection ON/OFF OFF
P33 Electric lock activation time From 0 to 10 seconds 3
P34 Selects the operation of the second
button on the remote control
2CH= activates the 2CH output
PED= controls pedestrian opening
PED
P35 Channel 2 output activation time From 1 to 60 seconds
1
P36 Pedestrian opening distance From 1 to 100% of total travel 100%
P37 Flashing light active also when run-
ning only on battery
ON/OFF OFF
P38 Operation with battery 0: functionality does not change
1: after an apch command the gate opens and remains open
2: the gate opens and remains open
0
P39 Manned 0: function disabled
1: function active if the safety devices are open (PHOTO and
STPA) controlled by APCH for opening and by Aped for closing
2: function active with apch and ped inputs, maintains automatic
operation if controlled remotely, controlled by APCH for opening
and by Aped for closing
0
P40 Detection of stop when closing Adjusts the space in which the card does not command reversal
on an obstacle as it believes to have reached the mechanical
stop position for closing.The higher the value of the parameter,
the greater the space.
Small values (small space) are best suited for short leaves, larger
values (larger space) are suitable for longer leaves.
0 (minimum value)
5 (maximum value)
1
P41 The higher the value of the param-
eter, the greater the space.
0= AP/CH controls complete opening and closing of the gate,
PED controls partial opening and closing of the gate
1= input AP/CH controls opening only and input PED controls
closing only
2= input AP/CH and the button of the remote control saved as
CH1 controls opening only and the
PED input and the button of the remote control saved as CH2
controls closing only
0
P42 Operation with solar panel ON/OFF
OFF
P43 Type of gearmotors 1=EI20 underground at 12v to 2m
2=ZI27 underground at 12v to 3m
3=EA20 linear gearmotor 12V to 2m
4=EA25 linear gearmotor 12V to 2.5m
5=EA50 linear gearmotor 12V to 3.5m
4
P44 Unused Leave OFF OFF
P45 Unused Leave OFF OFF
SINGLE LEAF: If you are using the control panel to govern a single leaf, connect the motor to output M1 and proceed with the calibration of the travel,
the control panel is congured automatically for single-leaf operation, after calibration parameters 10-12-14-16-18 -20-22-24-26-29-30 will no longer
be active
OPERATION WITH NO ENCODER: If no encoder is connected you need to remove the encoder interface card before powering up the control panel,
parameters 13-14-15-16-17-25-26 are in any case active
N.B:
Encoder present:
After calibrating the travel, if you change the parameters 13-14-15-16-17-18-19-20 and 43 after conrming with the OK button the display will show
A.P.C.H., it is necessary to issue the command with the APCH button, the gate will perform a complete opening and closing action (with this operation,
the control panel saves the new current thresholds with the modied speeds).
Encoder not present:
It is necessary to calibrate the travel of the leaves again, the display will show LRN. The APCH, APED and radio commands are ignored until learning is
accomplished.”
7.5 DEF: used to set the control panel on the default parameters via parameters 9-10-11-12-29-30-31-36-40, press and release the OK button, the
display shows 4 dots to conrm the operation.
x5
EN