EMC® VNX5300™ Hardware Information Guide
22
EMC® VNX5300™ Hardware Information Guide
Figure 16 shows the location of these components.
Figure 16 Example of SP components (rear view)
1 AC power in connector (recessed plug) 8 Two RJ-45 (management and service laptop)
connectors (labeled with a network management
symbol and a wrench symbol, respectively)
2 Power supply fault LED (amber) 9 SP unsafe to remove LED
3 Power supply power on LED (green) 10 SP fault LED (amber)
4 Power supply latch handle 11 SP power on LED (green)
5 Two I/O module slots showing one four-port
8-Gb/s Fibre Channel (FC) I/O module and one
four-port 1-Gb/s iSCSI I/O module
12 Two RS-232/EIA (micro DB-9) connectors
(labeled with a battery symbol and a wrench
symbol, respectively)
6 Two SP latch handles (bottom left and right) 13 Four 8-Gb/s Fibre Channel ports (labeled 8Gb
fibre 2, 3, 4, and 5)
7 Two 6-Gb/s SAS ports
X4
2
3
4
5
6Gb
SAS
8Gb
bre
1
0 X4
6Gb SAS
Cover
Do not remove
Cover
Do not remove
5
1
7 6
13
1112
VNX-000285
2
4
3
10
9
8