System component description
VNX5500 Hardware Information Guide 45
Data Mover management module Ethernet (RJ-45) NIC ports
The Block and File (Unified) VNX5500 platform Data Mover management module comes
with three integrated dual-port Ethernet ports (labeled 0, 1, and 2) on the rear. These
ports support an interface for connecting to 10-Mb/s, 100-Mb/s, or 1000-Mb/s networks
and provide full-duplex (FDX) capability, which enables simultaneous transmission and
reception of data.

To avoid electric shock, do not connect safety extra-low voltage (SELV) circuits to
telephone-network voltage (TNV) circuits. LAN ports contain SELV circuits, and WAN ports
contain TNV circuits. Some LAN and WAN ports both use RJ-45 connectors. Use caution
when connecting cables.
To access the Ethernet ports, connect a Category 3, 4, 5, 5E, or 6 unshielded twisted-pair
(UTP) cable to the RJ-45 connector on the back of the Data Mover management module, as
described in Table 16 on page 34.
Since the Control Station and the Data Mover management module have the same type of
RJ-45 NIC ports, the “Control Station Ethernet (RJ-45) NIC ports” on page 40 provide
detailed information about the Data Mover management module NIC ports.
Data Mover management module LEDs
Figure 38 shows the LEDs and Table 26 on page 46 describes them.
Figure 38 Data Mover management module LEDs
2
0
1
#
Port 2 (Link LED)
Port 0 (Link LED)
Numeric display
(DME ID)
Port 1 (Activity LED)
Power/Fault LED
Port 0 (Activity LED)
Port 2 (Activity LED)
Port 1 (Link LED)