Certificate
Baseefa07ATEX0057X
Standards
EN 60079-0: 2012, EN 60079-31: 2009
Markings
II 3 D Ex tc IIIC T135 °C Dc, (-40 °C ≤ T
a
≤ +65 °C)
Special Conditions for Safe Use(X)
1. The surface resistivity of the antenna is greater than 1GΩ. To avoid
electrostatic charge build-up, it must not be rubbed with a dry cloth
or cleaned with solvents.
9.9 International
N7 IECEx Type n
Certificate
IECEx BAS 07.0012X
Standards
IEC 60079-0: 2011, IEC 60079-15: 2010
Markings
Ex nA IIC T4 Gc, T4(-40 °C ≤ T
a
≤ +65 °C), V
MAX
= 28 Vdc
Special Conditions for Safe Use(X)
1. The apparatus is not capable of withstanding the 500 V electrical
strength test as defined in Clause 6.5.1 of IEC 60079-15:2012. This
must be taken into account during installation.
2. The surface resistivity of the antenna is greater than 1GΩ. To avoid
electrostatic charge build-up, it must not be rubbed with a dry cloth
or cleaned with solvents.
NF IECEx Dust
Certificate
IECEx BAS 07.0013
Standards
IEC 60079-0: 2011, IEC 60079-31: 2008
Markings
Ex tc IIIC T135 °C Dc, (-40 °C ≤ T
a
≤ +65 °C)
Special Conditions for Safe Use(X)
1. The surface resistivity of the antenna is greater than 1GΩ. To avoid
electrostatic charge build-up, it must not be rubbed with a dry cloth
or cleaned with solvents.
9.10
Brazil
N2 INMETRO Type n
Certificate
UL-BR 15.0350X
Standards
ABNT NBR IEC 60079-0:2008 + Errata 1:2011, IEC
60079-15:2012;