Model Programming Choices
1F95-1291
7 Day 5+1+1 Day Non-Programmable
www.white-rodgers.com
www.emersonclimate.com
Big Blue Humidity Universal Thermostat
with Humidity/Dehumidity Control and
Automatic Heat/Cool Changeover Option
PART NO. 37-7313B
Replaces 37-7313A
1241
Single Stage, Multi-Stage, Heat Pump
Installation and Operating Instructions
APPLICATIONS
SPECIFICATIONS
1F95-1291 Humidity Control Touchscreen Thermostat
Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS
CAREFULLY BEFORE INSTALLING OR OPERATING THIS
CONTROL COULD CAUSE PERSONAL INJURY AND/OR
PROPERTY DAMAGE.
THERMOSTAT APPLICATION GUIDE
Thermostat
Configuration Options
Thermostat
Applications
Maximum
Stages
Heat/Cool
Single Stage 1
No Heat Pump (SS1)
Gas, Oil, Electric, Heat Only,
Cool Only or Heat/Cool
Systems, 2 or 3 wire Hydronic
Zone (Hot Water or Steam)
Systems, 24 Volt or Millivolt
1+1
Multi Stage 2
No Heat Pump (MS2)
2+2
Heat Pump 1
Single Stage Compressor
Heat Pump (HP1)
Single Stage Compressor
Heat Pump Systems - up to 2
Stages Aux./Emergency Heat
3+1
Heat Pump 2
Two Stage or Two
Compressor Heat Pump
(HP2)
Two Stage or Two Compressor
Heat Pump systems - up to 2
Stages Aux./Emergency Heat
4+2
ATTENTION: MERCURY NOTICE
This product does not contain mercury. However, this prod-
uct may replace a product that contains mercury.
Mercury and products containing mercury must not be
discarded in household trash. Do not touch any spilled
mercury. Wearing non-absorbent gloves, clean up any
spilled mercury and place in a sealed container. For proper
disposal of a product containing mercury or a sealed
container of spilled mercury, place it in a suitable shipping
container. Refer to www.thermostat-recycle.org for loca-
tion to send the product containing mercury.
Index Page
Installation 2
Wiring Diagrams 3
Thermostat Quick Reference 5
Installer Configuration Menu 6
Operating Your Thermostat 10
Programming 12
Troubleshooting 15
Electrical Rating:
Battery Power .......................... mV to 30 VAC, NEC Class II, 50/60 Hz or DC
Input-Hardwire ......................... 20 to 30 VAC
Terminal Load ............................. 1.5A per terminal, 2.5A maximum all terminals combined
Setpoint Range ............................ 45 to 99°F (7 to 37°C)
Rated Differentials: Fast. Slow
Heat (Single Stage/Multi-Stage) ............ 0.6°F 1.5°F
Cool (Single Stage/Multi-Stage) ............ 1.2°F 1.7°F
Heat Pump ............................ 1.2°F 1.7°F
Emer Heat ............................ 0.6°F 1.7°F
Operating Ambient.......................... 32°F to +105°F (0 to +41°C)
Operating Humidity ......................... 90% non-condensing max.
Shipping Temperature Range ................. -40 to +150°F (-40 to +65°C)
Dimensions Thermostat...................... 4-9/16"H x 5-13/16"W x 1-3/16"D
Humidity Setpoint Range..................... 5 to 50%
Dehumidification Setpoint Range .............. 40 to 95%
To prevent electrical shock and/or equipment damage,
disconnect electric power to system at main fuse or
circuit breaker box until installation is complete.
CAUTION
!
Question and Answer IconNeed help?

Do you have a question about the Emerson 1F95-1291 and is the answer not in the manual?

Emerson 1F95-1291 Specifications

General IconGeneral
TypeProgrammable Thermostat
Wi-Fi EnabledYes
Schedule7-day programmable
Temperature Range45°F to 90°F (7°C to 32°C)
FeaturesSmart alerts
Voltage24VAC
Accuracy±1°F (±0.5°C)
CompatibilitySingle-stage heating and cooling systems

Summary

Safety and Notices

Installation Caution

Warning about electrical shock and equipment damage during installation.

Installation Procedures

Safety and Preparation

Includes safety warnings and steps for removing the old thermostat.

Wiring Diagrams

Thermostat Quick Reference

Programming and Configuration Item Descriptions

Details the function of various programming and configuration items identified by numbers.

Installer Configuration Menu

System and Schedule Configuration

Sets system type, reversing valve, programming schedule, and fan operation.

Installer Configuration Menu - Advanced Settings

Dual Fuel and Compressor Control

Settings for dual fuel operation, compressor delay, auxiliary heat, and blower balance point.

Humidity and Dehumidification Control

Configuration for humidity display, auto reduction, and dehumidification modes.

Installer Configuration Menu - Display and Control

System Protection and Limits

Configuration for compressor optimization, comfort alert, and temperature limit ranges.

Installer Configuration Menu - Lockout and Special Functions

Keypad Lockout and Security

Options for total or partial keypad lockout and setting security combinations.

Operating Your Thermostat

Operating Your Thermostat - Modes

Emergency Heat Mode

Details on activating and using the Emergency Heat mode for heat pump systems.

Cooling/Dehumidifier Operation

Instructions for testing cooling and dehumidification functions, including setpoint adjustments.

Programming

Programming - Cooling and Auto Schedule

Automatic Schedule

How to use Auto Schedule for fast programming of heating and cooling temperatures.

Programming - Worksheets and Planning

Wired Remote Temperature Sensing

Information on installing and configuring wired remote temperature sensors.

Programming - Advanced Settings

Averaging or Weighting Remote Sensors

Explains how to average or weight remote sensor temperatures with the local sensor.

Troubleshooting

Troubleshooting - Common Issues

Reset Operation