Electrical Rating:
Battery Power ..................................... mV to 30 VAC, NEC Class II, 50/60 Hz
Input-Hardwire .................................... 20 to 30 VAC, NEC Class II, 50/60 Hz
Terminal Load .......................................... 1.0 A per terminal, 1.5A maximum all terminals combined
Setpoint Range ........................................ 45° to 99° F (to 37° C)
Rated Dierentials: Fast Med Slow
Heat (@ 6°F/ Hr) .................................. 0.5°F 0.75°F 1.9°F
Cool (@ 6°F/ Hr) .................................. 0.9°F 1.2°F 1.7°F
Operating Ambient .................................. 32°F to +105°F (0° to +41°C)
Display Temperature Range ....................... 32°F to +99°F (0 to 37°C)
Operating Humidity ................................. 90% non-condensing max
Shipping Temperature Range ................... -20°F to + 150°F (-29° to +65°C)
Thermostat Dimensions ........................... 3-3/4” H x 6” W x 1-1/8” D
PART NO. 37-7841001
2052
1F75C-11PR (Programmable)
Installation and Operating Instructions
Single Stage Thermostat
Battery Powered or Hardwired with Common
Thermostat Applications
Maximum
Stages
Heat/Cool
Conventional Gas, Oil, Electric (mV and
24V), Heat Only, Cool Only or Heat/
Cool Systems
1/1
Heat Pump (air source or geothermal)
with no Aux. Heat
1/1
Thermostat Installation
2-4
Wiring
2
Installer Menu
3-4
Test Equipment
4
Using the Thermostat
5-7
Thermostat Overview
5
Thermostat Operation
6
Thermostat Schedule/Programming
6-7
Troubleshooting
7-8
Homeowner Help Line
8
INDEX
SPECIFICATIONS
MERCURY NOTICE: This product does not contain
mercury. However, this product may replace a product
that contains mercury. Mercury and products containing
mercury must not be discarded in household trash.
Refer to www.thermostat-recycle.org for information
on disposing of products containing mercury.
Paramètres électriques :
Batterie ..................................................... 20 à 30 V c.a., NEC classe II, 50/60 Hz
Câblé ........................................................ 20 à 30 V c.a., NEC classe II, 50/60 Hz
Charge à la borne ........................................... 1,0 A par borne, 1,5 A maximum pour toutes les bornes combinées
Plage de réglage ............................................ 45 à 99 °F (7 à 37 °C)
Diérentiel nominal : Rapide Moyen Lent
Chauage (@ 6 °F/h) ................................ 0,5 °F 0,75 °F 1,9 °F
Climatisation (@ 6 °F/h) ............................ 0,9 °F 1,2 °F 1,7 °F
Température ambiante de fonctionnement ... 32 °F à +105 °F (0 à +41 °C)
Plage de températures achées ...................... 32 °F à +99 °F (0 à +37 °C)
Humidité de fonctionnement ......................... 90 % max. sans condensation
Plage de températures d’expédition ............... -20 °F à +150 °F (-29 à +65 °C)
Dimensions du thermostat ............................. 3-3/4 po H x 6 po L x 1-1/8 po P
1F75C-11PR (programmable)
Instructions d’installation et d’utilisation
Thermostat avec thermopompe série 80
Alimentation par piles ou câblée avec l commun
Applications du thermostat
Nombre
maximum
d’étages
chauage/
climatisation
Systèmes au gaz conventionnels, au
mazout, à l’électricité (mV et 24 V),
chauage seulement, climatisation
seulement ou chauage et climatisation
1/1
Thermopompe (source d’air ou
géothermique) sans chauage auxiliaire
1/1
Installation du thermostat
2-4
Câblage
2
Menu de l’installateur
3-4
Équipement du test
4
Utilisation du thermostat
5-7
Aperçu du thermostat
5
Fonctionnement du thermostat
6
Programmation du thermostat
6-7
Dépannage
7-8
Ligne d’assistance pour les propriétaires
8
INDEX
SPÉCIFICATIONS
AVIS RELATIF AU MERCURE : Ce produit ne contient pas
de mercure. Il peut toutefois remplacer un produit qui en
contient. Le mercure et les produits contenant du mercure
ne doivent pas être jetés dans les ordures ménagères.
Consultez le site www.thermostat-recycle.org pour
connaître les endroits où vous pouvez envoyer le produit
contenant du mercure.
Accessoire en opon :
plaque murale F61-2663,
6 3/4 po L x 4 1/2 po H
N
O
DE PIÈCE 37-7841001
2052
emerson.com/white-rodgers
emerson.com/white-rodgers
Optional Accessory: Wall
Cover-Up Plate F61-2663,
6 3/4” W x 4 1/2” H
Programming
made Simple
See page 7

Questions and Answers

  • S
    sophia77Aug 4, 2025
    How to fix no heat on my Emerson 1F75C-11PR?
    • M
      Morgan Black MDAug 5, 2025
      If your Emerson Thermostat isn't producing heat, ensure that: * The System Switch is set to Heat and the setpoint is above room temperature. * Thermostat and system wires are securely attached. If the thermostat doesn't click after being reset, contact your heating and cooling service person or place of purchase for a replacement.
  • J
    John SmithAug 9, 2025
    What to do if my Emerson Thermostat is not cooling?
    • D
      David FarmerAug 9, 2025
      If your Emerson Thermostat isn't providing cool air, make sure that: * The System Switch is set to Cool and the setpoint is below room temperature. * Thermostat and system wires are securely attached. If this doesn't resolve the issue, follow the same diagnostic procedures as for a 'No Heat' condition, ensuring the thermostat is set to Cool and the setpoint is lower than the room temperature.
  • F
    frank02Aug 14, 2025
    How to troubleshoot no heat, no cool, or no fan on my Emerson Thermostat?
    • J
      Joshua GarciaAug 14, 2025
      If your Emerson Thermostat isn't providing heat, cool, or fan functions, there are several possible causes: * A blown fuse or tripped circuit breaker: Replace the fuse or reset the breaker. * The furnace power switch is OFF: Turn the switch ON. * The furnace blower compartment door panel is loose or improperly installed: Replace the door panel correctly to engage the safety interlock or door switch. * There's a loose connection to the thermostat or system: Tighten the connections.
  • H
    hernandezjamesAug 25, 2025
    What to do if the “Call for Service” icon appears on my Emerson Thermostat?
    • G
      gserranoAug 25, 2025
      If the “Call for Service” icon appears on your Emerson Thermostat display, it could mean a few things: * The heating system can't heat the space to within 10 degrees of the setpoint within 2 hours: See corrective action for 'No Heat'. * The cooling system can't cool the space to within 10 degrees of the setpoint within 2 hours: See corrective action for 'No Cool'. * If “--” is displayed for the Room Temperature: Replace the thermostat. * None of the buttons operate on the thermostat: Make sure keypad lockout is not turned on (denoted by icon).
  • B
    Benjamin OrtegaAug 29, 2025
    Why does my Emerson 1F75C-11PR Thermostat cycle too fast?
    • V
      Victoria WrightAug 29, 2025
      The location of the thermostat or the size of the heating system can affect the cycle rate. To increase cycle time on your Emerson Thermostat, select SLO for slow cycle in the Installer menu.
  • S
    Samantha BrooksSep 10, 2025
    Why does the heat, cool, or fan run constantly on my Emerson 1F75C-11PR Thermostat?
    • H
      heather99Sep 12, 2025
      If your Emerson Thermostat is running constantly, there might be a short in the wiring, thermostat, or the heating, cooling, or fan system. Check each wire connection to ensure they are not shorted or touching other wires.

Summary

Thermostat Installation

Wiring

Details on connecting wires to thermostat terminals for different systems.

Installer Menu Settings

Configuration Options

Covers Gas/Elec switch, O/B terminal switch, and RC/RH jumper wire settings.

Test Equipment

Heating and Cooling System Checks

Procedure for testing heating and cooling system operation.

Using the Thermostat

Thermostat Overview and Controls

Explanation of thermostat buttons, switches, and display elements.

Thermostat Operation

Setting Time and Day

Guide for setting the current time and day on the thermostat.

Programming Schedules

Instructions for setting heating and cooling schedules.

Troubleshooting

Common Symptoms and Solutions

Addresses issues like no heat/cool, constant runs, and display errors.

Resetting Thermostat Settings

Procedure for resetting schedule and user settings to factory defaults.

Emerson 1F75C-11PR Specifications

General IconGeneral
BrandEmerson
Model1F75C-11PR
CategoryThermostat
LanguageEnglish