Table A-11: Machine Temperature
(continued)
Axis Severity Upper Limit Lower Limit Units Notes
Machine
Temperature
Sensor 95 -50 °C Read-only
Machine
Temperature
Range 95 -50 °C Can be set by
the user up to
the sensor
range
Machine Temp Fail 75 -40 °C
Machine
Temperature
Maint 70 -35 °C
Machine
Temperature
Advise 65 -30 °C
Table A-12: Supply Voltage
Axis Severity Upper Limit Lower Limit Units Notes
Supply
Voltage
Saturated 3.75 0 V Read-only
Supply
Voltage
Sensor 3.75 0 V Read-only
Supply
Voltage
Range 3.7 2.3 V Read-only
Supply
Voltage
Fail Not Applicable 2.7 V Read-only
Supply
Voltage
Maint Not Applicable 2.85 V
Supply
Voltage
Advise Not Applicable 3 V
Table A-13: Speed
Axis Severity Upper Limit Lower Limit Units Notes
Speed Saturated 10000 0 rpm Limits
calculated by
device and not
user settable.
Speed Sensor 10000 0 rpm Limits
calculated by
device and not
user settable.
Speed Range 3000 0 rpm Limits
calculated by
device and not
user settable.
Specifications and reference data User Guide
August 2020 MHM-97927-PBF
70 MHM-97927-PBF, Rev 1

Related product manuals