EasyManua.ls Logo

Emerson Bettis CBB Series - Page 16

Emerson Bettis CBB Series
25 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
May 2012
Service Instructions
137465E Rev. F
13
Section 3: Actuator Reassembly
Actuator Resassembly
NOTE:
While holding the center bar assembly ush against the housing, push piston (4-50) into
housing (1-10) as far as the piston will go.
3.3.7 Apply a coating of lubricant to entire bore of spring cylinder (4-10).
3.3.8 Spring cylinder installation:
3.3.8.1 For CBB415-SR, CBB520-SR and CBB725-SR models install the lubricated
spring cylinder (4-10) over the piston and up-against the o-ring seal on
the stepped diameter ange of cylinder adapter (4-15).
3.3.8.2 For CBB315-SR, CBB420-SR and CBB525-SR models install the lubricated
spring cylinder (4-10) over the piston and up-against the o-ring seal on
the ange of housing (1-10).
3.3.9 Install spacer (1-110) onto center bar assembly (8-10).
3.3.10 Apply a coat of lubricant to the spring (4-70). Install the spring into the spring
cylinder by carefully sliding the spring into the open spring cylinder end until the
spring contacts the head of piston (4-50).
3.3.11 End cap seal installation.
3.3.11.1 For CBB415-SR, CBB520-SR and CBB725-SR models install O-ring seal
(5-15) onto end cap (4-20).
3.3.11.2 For CBB315-SR, CBB420-SR and CBB525-SR models install O-ring seal
(5-10) onto end cap (4-20).
3.3.12 If removed install stop screw / ES (4-30) into end cap (4-20) and set stop screw to
the approximated setting recorded in Section 2 step 2.1.2.
NOTE:
Position spring cylinder (4-10) so that spring tag (4-60) will be adjacent to accessory
mounting pads located on the actuator housing.
3.3.13 Install end cap (4-20) onto center bar assembly (8-10) by rotating the end cap in a
clockwise direction.
3.3.14 Position the end cap (4-20) so that the breather port is at the bottom and the stop
screw / ES (4-30) is at the top.
WARNING: END CAP INSTALLATION
Do not allow end cap (4-20) to rotate during center bar assembly tightening. The end cap
must maintain the position as described in step 3.3.14.
3.3.15 Keep end cap (4-20) from turning by holding end cap with an adjustable wrench.
3.3.16 Using a ratchet and socket on the center bar assembly nut, rotate center bar
assembly clockwise (CW). This will cause end cap (4-20) to gradually screw further
onto center bar assembly (8-10).