EasyManua.ls Logo

Emerson Bettis CBB Series - Section 2: Actuator Disassembly; General Disassembly and Pressure Release

Emerson Bettis CBB Series
25 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Service Instructions
137465E Rev. F
May 2012
6
Section 2: Actuator Disassembly
Actuator Disassembly
2�2 Spring cylinder disassembly
NOTE:
Review Section 2 steps 2.1.1 through 2.1.2 before proceeding with cylinder disassembly.
CAUTION: SPRINGS ARE PRELOADED
The spring in CBB Series Spring Return Actuators are preloaded.
WARNING: POTENTIALLY DANGEROUS DISASSEMBLY
Actuator must be disassembled in the following manner.
2.2.1 Remove hex nut (1-80) as follows: CBB315 through 725 standard housing stop
screw or extended stop (ES) use step 2.2.1.1. CBB315-SR-M3/M3HW through
CBB725-SR-M3/M3HW use step 2.2.1.2.
2.2.1.1 For CBB315 through 725 housing stop screw or extended stop screw
(ES):
2.2.1.1.1 Loosen and remove hex nut (1-80) and washer (1-90) from stop
screw (1-70) located in housing (1-10).
2.2.1.1.2 Remove stop screw (1-70) located in housing (1-10).
2.2.1.2 For CBB315/420/520/525/725-SR-M3 or M3HW:
2.2.1.2.1 Remove retainer ring (12-30) and groove pin (12-20) from
optional hex drive hub or from hand wheel (12-10).
2.2.1.2.2 Remove optional hex drive hub or handwheel (12-10) from M3
jackscrew (1-70).
2.2.1.2.3 Loosen and remove hex nut (1-80) from M3 jackscrew (1-70).
NOTE:
CBB420,520,525,725-SR-M3 or M3HW models: the M3 jackscrew (1-70) can not be removed now.
The M3 jackscrew used in these models can be removed later in this procedure per step 2.3.7.
2.2.2 Loosen and remove hex nut (4-40) and washer (4-90) from end cap stop screw
(4-30) or from end cap extended stop (4-30).
NOTE:
Extended stop or end cap stop screw (4-30) does not require removal from end cap (4-20)
unless replacing with a new extended stop or stop screw.
2.2.3 Remove breather (30) from end cap (4-20).
2.2.4 Remove acorn nut (8-20) and gasket seal (5-50) from end cap (4-20).
2.2.5 Use a ratchet and socket on the welded nut, located on the housing end of center bar
assembly (8-10), rotate center bar assembly (8-10) counter-clockwise (CCW). This
will cause end cap (4-20) to gradually unscrew from center bar assembly (8-10).