Mar 2013
Installation and Maintenance
Part Number: E2K-402-0313, Rev. A
10
Section 4: Limit Switch Setting Instructions
Limit Switch Setting Instructions
2. Disengage spring loaded gear: Push Disengage Shaft in (g. 7a) down, then rotate
90° so shaft is captured down. This will disengage limit switch gears from spring
loaded drive gear.
TIP:
Many turns may be required to set limit switches; it may be convenient to use a
reversible variable speed drill to rotate the adjusting shafts instead of a screw-
driver.
Figure 7