Installation and Maintenance
Part Number: E2K-402-0313, Rev. A
Mar 2013
13
Section 4: Limit Switch Setting Instructions
Limit Switch Setting Instructions
4.6 To Set Open Torque Switch (TSO)
a) Follow procedure as for TSC at TSO dial.
4.7 Torque Switch Rotation Limit
Adjustment rotation may be limited, Remove dial to expose anti-rotation pins. Remove
pins from position 10 and insert into the desired hole.
Figure 10