7. Wall Control Procedures (continued)
3-WAY WIRING DIAGRAM:
NEW CONSTRUCTION
NOTE: Retrofit 3-way installations are likely to
include two traveler wires between the two wall
boxes. In new construction, only one traveler wire Is
required (See Figure 23).
7.19
Screw wall control into wall box using the supplied
screws. Leave wall control in “OFF” mode until fan
installation is completed.
7.20
The wall control is supplied with a white, ivory, and
almond color switch covers. Choose the finish that best
suits your needs and snap the cover onto the wall
control (Figure 23).
7.21
Next, install the other wall control into the wall box
containing the load wire. Connect the black wire of the
wall control to the traveler wire(s) already connected to
the black wire (in the other wall box). Secure with wire
connectors supplied.
7.22
Connect one black wire of the wall control to the “load”
(black) wire and secure with wire connector supplied.
7.23
Connect one black wire of the wall control to both
remaining traveler wires in the wall box and secure with
wire connector supplied.
Figure 23
Check to see that all connections are tight and that no
bare wires are visible at the wire connectors.
WARNING
!
STANDARD WIRING FOR EXISTING
3-WAY CONTROLS