23
Installation
Figure 18: EN Input/Output Wiring Diagram
Note
The I/O connector is a 10-pin removable terminal block. It is recommended that #18 to 24
AWG stranded wire be used.
Figure 19: EN I/O Connector to Command Connector Internal Connections
Front View
I/O supply
+10 to 30 VDC
2.8 k
Load
Load
Load
A highspeed diode
(such as a 1N5819) is
required for inductive
loads such as a relay,
solenoid or contactor.
J6
-
+
24 VDC
1 Amp Fuse
Single point
PE ground.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com