Installation
Figure 86: Pulse/Pulse Mode, Single Ended Output to Single Ended Input (non-twisted
pair cable)
Figure 87: Master/Slave Encoder Connections
Note
Encoder outputs meet RS-422 driver specifications and can drive up to 10 RS-422 signal
receivers. Each differential pulse input is an RS-422 line receivers. The default encoder
Common isolated
from other sources
Sinking
Outputs (typ)
+5
Logic
Power
CW Pulse
CCW Pulse
CCW Pulse
CW Pulse
R1, R2, and R3 must be mounted within 6" of the end drive.
A 120 ohm resistor is recommended for high frequency
(over 250 kHz) stepping or cable lengths longer
than 25 feet.
Note:
Master Encoder
or Drive Output
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com