EasyManua.ls Logo

Emerson Copeland EV2 Series - Page 18

Emerson Copeland EV2 Series
27 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
78
1st Fault
Occurred
(Read)
AC Input Over Current
Immediate
Shutdown
N/A
Bit 1
0 = No ; 1 = Yes
DC Bus Over Voltage
Immediate
Shutdown
N/A
Bit 2
0 = No ; 1 = Yes
DC Bus Under Voltage
Immediate
Shutdown
N/A
Bit 3
0 = No ; 1 = Yes
AC Input Over Voltage
Immediate
Shutdown
N/A
Bit 4
0 = No ; 1 = Yes
AC Input Under Voltage
Immediate
Shutdown
N/A
Bit 5
0 = No ; 1 = Yes
Sensor 1 (High Pressure
Switch Open)
Immediate
Shutdown
N/A
Bit 8
0 = No ; 1 = Yes
Power Module Over Temp
Immediate
Shutdown
N/A
Bit 11
0 = No ; 1 = Yes
IGBT Over Temp
Immediate
Shutdown
N/A
Bit 12
0 = No ; 1 = Yes
Lost Rotor Position
Immediate
Shutdown
N/A
Bit 13
0 = No ; 1 = Yes
Lockout (After 10 fault occurrences*)
Pre-charge Relay Open
N/A
N/A
Bit 15
0 = No ; 1 = Yes
79
1st Fault
Occurred
(Read)
DC Bus Voltage Low
N/A
N/A
Bit 0
0 = No ; 1 = Yes
Torque Limit Fold Back
Timeout
Controlled
Shutdown
N/A
Bit 2
0 = No ; 1 = Yes
Power Module Temp. Fold
Back Timeout
Controlled
Shutdown
N/A
Bit 3
0 = No ; 1 = Yes
AC Input Current Fold Back
Timeout
Controlled
Shutdown
N/A
Bit 4
0 = No ; 1 = Yes
Auto Config Communication
Timeout
N/A
N/A
Bit 6
0 = No ; 1 = Yes
Modbus Communication Lost
Controlled
Shutdown
N/A
Bit 7
0 = No ; 1 = Yes
Sensor 2 (Thermistor, DLT)
High Temp
Controlled
Shutdown
N/A
Bit 8
0 = No ; 1 = Yes
Board Temp High
Controlled
Shutdown
N/A
Bit 10
0 = No ; 1 = Yes
Power Module Temp High
Controlled
Shutdown
N/A
Bit 11
0 = No ; 1 = Yes
IGBT Temp High
Controlled
Shutdown
N/A
Bit 12
0 = No ; 1 = Yes
80
Multiple Faults
Occurred
(Read)
Compressor Phase Over
Current
Immediate
Shutdown
N/A
Bit 0
0 = No ; 1 = Yes
Lockout (After 10 fault occurrences*)
AC Input Over Current
Immediate
Shutdown
N/A
Bit 1
0 = No ; 1 = Yes
DC Bus Over Voltage
Immediate
Shutdown
N/A
Bit 2
0 = No ; 1 = Yes
DC Bus Under Voltage
Immediate
Shutdown
N/A
Bit 3
0 = No ; 1 = Yes
AC Input Over Voltage
Immediate
Shutdown
N/A
Bit 4
0 = No ; 1 = Yes
AC Input Under Voltage
Immediate
Shutdown
N/A
Bit 5
0 = No ; 1 = Yes
Sensor 1 (High Pressure
Switch Open)
Immediate
Shutdown
N/A
Bit 8
0 = No ; 1 = Yes
Power Module Over Temp
Immediate
Shutdown
N/A
Bit 11
0 = No ; 1 = Yes
IGBT Over Temp
Immediate
Shutdown
N/A
Bit 12
0 = No ; 1 = Yes
Lost Rotor Position
Immediate
Shutdown
N/A
Bit 13
0 = No ; 1 = Yes
Lockout (After 10 fault occurrences*)
Pre-charge Relay Open
N/A
N/A
Bit 15
0 = No ; 1 = Yes
DC Bus Voltage Low
N/A
N/A
Bit 0
0 = No ; 1 = Yes
Torque Limit Fold Back
Timeout
Controlled
Shutdown
N/A
Bit 2
0 = No ; 1 = Yes

Related product manuals