FB1100/FB1200 Flow Computer Termination Board Field Replacement Guide
D301820X012
November 2020
12
Note
If you need more leverage place a long screwdriver or other appropriate tool across the
two notches in the cover to act as a pry bar.
Rear End Cap Removal
4.
Remove power at terminal block TB1.
5.
If your unit doesn’t include an internal battery, skip to Step 8. If the unit has an internal
battery which is connected, use a #1 Phillips-head screwdriver to loosen the four captive
fastening screws on the HMI module.
Captive Fastening Screws
6.
Grasp the HMI module and remove it by gently pulling it straight out.
7.
If battery-powered, disconnect the internal battery.