FB1100/FB1200 Flow Computer Sensor Assembly Field Replacement Guide
D301842X012
November 2020
v
Integral Sensor
Selection
MV 1500 psi absolute (103.4 bara)
Class 1 Div 2 UL, IEC Ex N, ATEX Ex N
Class 1 Div 1 UL, IEC Ex d, ATEX Ex d
A7
MV 3600 psi gauge (250 barg)
Note
: When used with 25" DP option, maximum working
pressure is 2000 psi/137.9 Bar.
Class 1 Div 2 UL, IEC Ex N, ATEX Ex N
Class 1 Div 1 UL, IEC Ex d, ATEX Ex d G4
MV 3600 psi absolute (250 bara)
Note
: When used with 25" DP option, maximum working
pressure is 2000 psi/137.9 Bar.
Class 1 Div 2 UL, IEC Ex N, ATEX Ex N
Class 1 Div 1 UL, IEC Ex d, ATEX Ex d A4
Static Pressure Range - for use only with Static Pressure Sensor (B1 or B2 above)
SP 150 psi gauge (10.34 barg)
Class 1 Div 2 UL, IEC Ex N, ATEX Ex N
Class 1 Div 1 UL, IEC Ex d, ATEX Ex d
G2
SP 150 psi absolute (10.34 bara)
Class 1 Div 2 UL, IEC Ex N, ATEX Ex N
Class 1 Div 1 UL, IEC Ex d, ATEX Ex d
A2
SP 800 psi gauge (55.15 barg)
Class 1 Div 2 UL, IEC Ex N, ATEX Ex N
Class 1 Div 1 UL, IEC Ex d, ATEX Ex d
G3
SP 800 psi absolute (55.15 bara)
Class 1 Div 2 UL, IEC Ex N, ATEX Ex N
Class 1 Div 1 UL, IEC Ex d, ATEX Ex d
A3
SP 4000 psi gauge (275.79 barg)
Class 1 Div 2 UL, IEC Ex N, ATEX Ex N
Class 1 Div 1 UL, IEC Ex d, ATEX Ex d
G4
SP 4000 psi absolute (275.79 bara)
Class 1 Div 2 UL, IEC Ex N, ATEX Ex N
Class 1 Div 1 UL, IEC Ex d, ATEX Ex d
A4
Sensor Material & Flange Type
Stainless Steel Sensor and Coplanar Flange
Class 1 Div 2 UL, IEC Ex N, ATEX Ex N
Class 1 Div 1 UL, IEC Ex d, ATEX Ex d
2E12
Hastelloy Diaphragm and Hastelloy Coplanar Flange
Note
: Not available with a 1000" 0.1% accuracy sensor or a
25" sensor.
Class 1 Div 2 UL, IEC Ex N, ATEX Ex N
Class 1 Div 1 UL, IEC Ex d, ATEX Ex d 3E13
Stainless Steel Sensor and Traditional Flange
Note: 0.1% Accuracy is not available on Traditional Flange.
Class 1 Div 2 UL, IEC Ex N, ATEX Ex N
Class 1 Div 1 UL, IEC Ex d, ATEX Ex d
2F12
Stainless Steel inline connection 1/2" 14 NPT Female - use
with Static Pressure only option B1 or B2 above
Class 1 Div 2 UL, IEC Ex N, ATEX Ex N
Class 1 Div 1 UL, IEC Ex d, ATEX Ex d
2K11
Sensor Material Certificates
Not Required
Class 1 Div 2 UL, IEC Ex N, ATEX Ex N
Class 1 Div 1 UL, IEC Ex d, ATEX Ex d
Q0R
3.1 B Traceability certs to EN 10205
Class 1 Div 2 UL, IEC Ex N, ATEX Ex N
Class 1 Div 1 UL, IEC Ex d, ATEX Ex d
Q8R
NACE MRO 175/ISO 15156 requires Hastelloy Diaphragm
Option
Note: Available only with 3E13.
Class 1 Div 2 UL, IEC Ex N, ATEX Ex N
Class 1 Div 1 UL, IEC Ex d, ATEX Ex d Q15R
NACE MRO 103 - requires Hastelloy Diaphragm Option
Note: Available only with 3E13.
Class 1 Div 2 UL, IEC Ex N, ATEX Ex N
Class 1 Div 1 UL, IEC Ex d, ATEX Ex d
Q25R
Calibration Certificate
Not Required
Class 1 Div 2 UL, IEC Ex N, ATEX Ex N
Class 1 Div 1 UL, IEC Ex d, ATEX Ex d
M0
Required
Class 1 Div 2 UL, IEC Ex N, ATEX Ex N
Class 1 Div 1 UL, IEC Ex d, ATEX Ex d
M4
Example Model Number: B222G72E12Q0RM4 - 250 Inches H2O (623 mbar) DP, 0.1% Accuracy, MV 1500 psi gauge,
Stainless Steel Sensor and Coplanar Flange, No Sensor Material Certificates Required, and Calibration Certificate
Required.