EasyManua.ls Logo

Emerson Fisher FIELDVUE DVC6200 Series - Before You Begin; Hazardous Area Approvals

Emerson Fisher FIELDVUE DVC6200 Series
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Instruction Manual Supplement
D104205X012
DVC6200 Digital Valve Controllers
November 2020
3
Type n II 3 G
WARNING
Do not open while energized.
Potential electrostatic charging hazard. See warning on page 1.
Covered by Standards:
 EN 60079-0:2012 + A11:2013
 EN 60079-15:2010
DVC6200 and DVC6205 Series (HART HW1 & HW2, SIS, F
OUNDATION Fieldbus, PROFIBUS)
Ex nC IIC T5 (Ta ≤ 80°C) / T6 (Ta ≤ 75°C) Gc
Operating ambient temperature
Standard construction -40_C to +80_C,
Extreme temperature construction -52_C to +80_C
DVC6215
Ex nA IIC T4 (Ta ≤ 125°C) / T5 (Ta ≤ 95°C) / T6 (Ta ≤ 80°C) Gc
Operating ambient temperature
 -52_C to +125°C

Other manuals for Emerson Fisher FIELDVUE DVC6200 Series