EasyManuals Logo

Emerson Fisher FIELDVUE DVC6200 Series Instruction Manual Supplement

Emerson Fisher FIELDVUE DVC6200 Series
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #8 background imageLoading...
Page #8 background image
Instruction Manual Supplement
D104205X012
DVC6200 Digital Valve Controllers
November 2020
8
1 SEE NOTES IN FIGURE 6
FISCO LOOP
ENTITY FIELDBUS LOOP
GE60771 Sheet 5, Rev D.
1 NOTE 5
NON‐HAZARDOUS LOCATION
ZONE 0, Ex ia IIC
ZONE 20, Ex ia IIIC
LOOP TERMINALS
Ui = 24 VDC
Ii = 380 mA
Ci = 5 nF
Li = 0 mH
Pi = 1.4 W
HAZARDOUS LOCATION
ATEX APPROVED
BARRIER
HAZARDOUS LOCATION
NON‐HAZARDOUS LOCATION
ATEX APPROVED
FISCO BARRIER
ATEX APPROVED
FISCO TERMINATOR
ATEX
APPROVED
FISCO DEVICE
LOOP TERMINALS
Ui = 17.5 VDC
Ii = 380 mA
Ci = 5 nF
Li = 0 mH
Pi = 5.32 W
ATEX
APPROVED
ENTITY DEVICE
NOTE 1, 3 1
1 NOTE 1, 3, 4
1 NOTE 2, 3, 4
NOTE 2, 3 1
Figure 3. ATEX Loop Schematics—FIELDVUE DVC6200f and DVC6200p
ZONE 0
Ex ia IIC
ZONE 20
Ex ia IIIC
ZONE 0, Ex ia IIC
ZONE 20, Ex ia IIIC
GE60771 Sheet 4, Rev. D
DVC6200F, DVC6200FS
DVC6200P, DVC6200PS
DVC6200F, DVC6200FS
DVC6200P, DVC6200PS
T CODE
T4
T5
T6
T AMB
80_C
77_C
62_C
MAX
SURFACE
TEMP
T103_C
T100_C
T85_C
T AMB
80_C
77_C
62_C
ZONE 0
Ex ia IIC
ZONE 20
Ex ia IIIC
T CODE
T4
T5
T6
T AMB
80_C
77_C
62_C
MAX
SURFACE
TEMP
T103_C
T100_C
T85_C
T AMB
80_C
77_C
62_C
1 SEE NOTES IN FIGURE 6

Other manuals for Emerson Fisher FIELDVUE DVC6200 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Fisher FIELDVUE DVC6200 Series and is the answer not in the manual?

Emerson Fisher FIELDVUE DVC6200 Series Specifications

General IconGeneral
ManufacturerEmerson
SeriesFIELDVUE DVC6200
TypeDigital Valve Controller
Communication ProtocolHART
Operating Temperature Range-40 to 85 °C (-40 to 185 °F)
Enclosure RatingNEMA 4X, IP66
MaterialAluminum, Stainless Steel
Hazardous Area CertificationsATEX, IECEx, FM, CSA
Input Signal4-20 mA, HART
Power SupplyLoop-powered
Supply Pressure1.4 to 6.0 bar
CertificationsSIL3 capable
DiagnosticsAdvanced Valve Diagnostics