© 2021 Emerson Climate Technologies Inc.
4
AE29-1468 R1
Introduction
The Lumity wireless data loggers measure temperature.
Designed to meet Centers for Disease Control and
Prevention (CDC) guidelines, this logger is ideal for
clinical applications, such as vaccines storage and other
Healthcare monitoring solutions. This BluetootLow
Energy-enabled logger is designed for wireless
communication with a mobile device. It also transmits
over 900 MHz frequency to TempTrak Server. Using the
Lumity Logger app, you can easily configure the device
with one of two different probe types Standard Probe or
Lab/Cryogenic probe for freezer or refrigerator
monitoring. You can also quickly perform daily device
checks, download reports, and monitor alarms. Use the
built-in LCD screen on the device to check the current
temperature, maximum or minimum temperatures,
alarms, battery use, and more.
Specifications
Lab/Cryogenic RTD
Temperature Probe
Model No. 10134 Comes with
Product Simulator Sleeve
(10184)
Temperature Range
-328°F to 311°F (-200°C to
155°C)
Accuracy
±0.5°C at 25°C (±1.0°F at
77°F)
NIST Calibration
Traceability available
Cable Length
10’ (3 m)
Probe Dimensions
Shaft diameter .25” (6 mm),
Shaft length 3” (76mm)
Sleeve Dimensions
2.0” x 1.5” dia. (51 mm x 38
mm dia.)
Standard
Temperature
Sensor
Model Number 10117
Temperature Range
-25° to 180°F (-32° to 82°C)
Accuracy
±0.5°C at 25°C (±1.0°F at
77°F)
Data Logger
Radio Frequency
Radio 1: 900 MHz Radio 2:
Bluetooth 4.1
Transmission Range
900MHz: 2500 feet (762
meters) (open field range) (To
be validated)
Bluetooth 4.1: 100 feet (30.5
meters) (open field range) (To
be validated)
Radio Power for
Bluetooth 5.0
1 mW (0 dBm)
Temperature
Accuracy
FX100 with Standard Probe:
±0.5°C from -50° to 150°C
(±0.9°F from -58° to 302°F)
FX100 with Lab/Cryogenic
RTD Probe:
±0.5°C from -200° to 180°C
(±0.9°F from -328° to 356°F)
±1.0°C from 180° to 500°C
(±1.8°F from 356° to 932°F)
Data Logger
Operating Range
-10° to 50°C (14° to 122°F), 0
to 95% RH (non-condensing)
Logging Rate
1, 5, 10, 15 or 20 Minute
Time Accuracy
±1 minute per month at 25°C
(77°F)
Battery Type
Two AA 1.5 V Lithium
Batteries, user replaceable
Battery Life
2 year, typical with logging
interval of 5 minutes. Faster
logging intervals, remaining
connected with the Lumity
Logger app, excessive report
generation & numerous