Section 4– Page 2
4.2 Standard Motor Configurations
The LX amplifiers can be easily configured for DX motors supplied by Emerson EMC by
using the settings in the following table.
Table 4-B – Settings for DX Motors OFF=0 ON=1
(Tabel 4-B – Rev. 01/13/95j)
SW 3/1,2 SW 2/1-/4
LX AMP MOTOR
R22
Ω
ΩΩ
Ω
# POLES
3/1 3/2
MOTOR
CURRENT
AMPS
2/1 2/2 2/3 2/4
DX-208 10K 4 1 0 2.16 0 0 0 0
400
DX-316 10K 6 0 1 2.97 0 1 1 0
DX-340 47K 6 0 1 6.14 1 0 1 0
700
DX-455 82K 6 0 1 7.32 1 1 1 1
DX-490 82K 6 0 1 10.99 1 1 1 1
1100
DX-4120 82K 6 0 1 10.99 1 1 1 1
Figure 4.1 Personality Board Dip Switch Locations
Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com