Configuration and Use Manual 55
Configuring the Filling and Dosing Application
Optional Configuration Using the FillerFiller ConfigurationUsing the Transmitter
Figure 7-1 Two-stage discrete fill
Figure 7-2 Three-position analog fill
0% (Begin)
Open Primary
100% (End)
Close Secondary
Open Primary at 0%
Close Primary before Close
Secondary
Close
Primary
Open
Secondary
Open
Primary
Open Secondary at 0%
Close Primary after Close
Secondary
Close
Secondary
0% (Begin)
Open Secondary
100% (End)
Close Primary
Primary valve
Secondary valve
Flow
Open
Primary
Open Secondary at 0%
Close Primary before Close
Secondary
Close
Primary
0% (Begin)
Open Secondary
100% (End)
Close Secondary
0% (Begin)
Open Primary
100% (End)
Close Primary
Open Primary at 0%
Close Primary after Close
Secondary
Close
Secondary
Open
Secondary
0%