Emerson Micro Motion Elite Coriolis CMFS100 User Manual

Emerson Micro Motion Elite Coriolis CMFS100
38 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Installation Manual
20002158, Rev DM
January 2018
Micro Motion
®
ELITE
®
Coriolis Flow and Density
Sensors
Question and Answer IconNeed help?

Do you have a question about the Emerson Micro Motion Elite Coriolis CMFS100 and is the answer not in the manual?

Emerson Micro Motion Elite Coriolis CMFS100 Specifications

General IconGeneral
TypeCoriolis Flow Meter
ModelCMFS100
Measurement PrincipleCoriolis
Fluid TypesLiquid, Gas
CategoryAccessories
ManufacturerEmerson
Output Signal4-20 mA, HART
Accessory TypeFlow Meter
ApplicationProcess measurement and control in industries such as oil & gas, chemical, food & beverage, pharmaceutical, and water & wastewater
CompatibilityEmerson Micro Motion Transmitters
Product LineMicro Motion
Pressure RangeUp to 1000 psig (69 bar)

Summary

Planning

Installation Checklist

Checklist for verifying environmental suitability and proper installation parameters.

Best Practices

Guidelines to optimize sensor performance and ensure correct installation procedures.

Temperature Limits

Defines the permissible ambient and process temperature ranges for sensor operation.

Hygienic and Self-Draining Applications

Recommendations for installing sensors in hygienic systems for optimal cleanability and drainage.

Mounting

Lifting Heavy Meters

Procedures and equipment recommendations for safely lifting and positioning heavy meter units.

Sensor Mounting

Instructions for installing the sensor, focusing on minimizing torque and bending load on connections.

Rotating Electronics Housing

Procedure for rotating the integrally mounted junction box or core processor in 45-degree increments.

High-Temperature Sensor Electronics Mounting

Steps for mounting electronics of high-temperature sensors separately from the sensor case via flexible conduit.

CMF010 Wall or Pole Mounting

Optional mounting configuration for CMF010 sensors for use with small or flexible pipelines.

CMFS007/010/015 Bracket Mounting

Procedure for using an optional mounting bracket for CMFS007, CMFS010, or CMFS015 sensors.

CMFS025/040/050 Wall Bracket Mounting

Instructions for mounting CMFS025, CMFS040, and CMFS050 sensors using an optional wall mount bracket.

Wafer-Style Process Connections

Guide on securing wafer-style sensors into the pipeline using a wafer installation kit and alignment rings.

Extended Electronics Attachment

Procedure for attaching an extender to the sensor case for installations with extended electronics.

Transmitter Power and I/O Wiring

Wiring Options

Explains wiring procedures based on the specific electronics option installed on the sensor.

4-Wire Cable Connection

Detailed guidance on preparing and connecting 4-wire cables for power and signal transmission.

9-Wire Cable Connection

Instructions for preparing and connecting 9-wire cables between the sensor and transmitter or core processor.

Grounding

Supplementary Information

Sensor Case Purging

Procedure for purging the sensor case with inert gas to remove oxygen and seal it.

Pressure Relief

Information regarding the rupture disk installed on the sensor case for venting process fluid in case of tube breach.