Specifications 11
Instruction Manual Section 2: Description and Specifications
LIQ-MAN-1066 April 2017
Ordering Information
The 1066 2-Wire Transmitter is intended for the continuous determination of pH, ORP (Redox),
conductivity, (both contacting and toroidal), and for measurements using membrane-covered
amperometric sensors (oxygen, ozone, free and total chlorine, and monochloramine). For free
chlorine measurements, which often require continuous pH correction a second input for a pH
sensor is available. Two 4-20mA analog outputs are standard on HART units. The 1066 is compat-
ible with SMART pH sensors from Rosemount. HART digital communications is standard and
FOUNDATION
®
fieldbus digital communication is offered as an option.
Communication with the 1066 is through:
Local keypad interface
475 HART
®
and FOUNDATION fieldbus Communicator
HART protocol version 7
F
OUNDATION fieldbus
AMS (Asset Management Solutions) Aware
SMART Wireless THUM
Adapter
2.9
TABLE 2-3. Ordering Information
Description
1066 pH/ORP, Conductivity, Chlorine, Oxygen, and Ozone 2-Wire Transmitter
Measurement
P pH/ORP
C Contacting Conductivity
T Toroidal Conductivity
CL Chlorine
DO Dissolved Oxygen
OZ Ozone
Communication
HT HART® Digital Communication Superimposed on 4-20mA Output
FF FOUNDATION™ fieldbus Digital Output
FI FOUNDATION™ fieldbus Digital Output with FISCO
Agency Approval
60 None Required
67
FM Approved, Intrinsically Safe (appropriate sensor & safety barrier
required), and Non-Incendive
69
CSA Approved , Intrinsically Safe (appropriate sensor & safety barrier
required), and Non-Incendive
73 ATEX/IECEx Approved, Intrinsically Safe (safety barrier required)