18. Make sure that cables are not pushed down in the space next to the IS Component
(if present), the cabling might otherwise impair Intrinsic Safety of the Board.
19. Arrange the cables so that they can't be damaged by the threads when mounting
the housing cover.
20. Snap on the Display cover or the Label Display Cover (depending on the version).
21. Inspect the O-ring on the housing cover, make sure it is not damaged, and if it is dry
apply some grease on the O-ring and the threads. Damaged O-ring must be
replaced with a new one.
22. Tighten the cover.
23. Remove the old label plate and replace it with the new one.
24. Apply the new main label on the plate.
25. Connect the device and power it on, if a display is present make sure the device is
working properly. When there is no display present contact the control room and
verify that the device is back on-line.
Manual Supplement Upgrade procedure
00809-0200-2410 January 2022
Rosemount 2410 Tank Hub 17