24
Manual Supplement
00809-0400-2410, Rev AA
Rosemount 2410 Tank Hub
March 2016
Rosemount 2410 Tank Hub
Table 1-6. Item Settings Requests
1.5.2 Input and holding registers
Measured data is continuously stored in input registers of the tank hub. By viewing the input
registers you can check that the device is working properly.
The holding registers store parameters which are used to configure the tank hub for various
applications. By using the TankMaster WinSetup program, holding registers can be edited
simply by typing a new value in the appropriate value input field. Some holding registers
can be edited in a separate window. In this case individual data bits can be changed.
To view input or holding registers, do the following:
1. In the TankMaster WinSetup workspace window, right click the tank hub device icon.
2. Choose the View Input Registers or View Holding Registers option.
TOR Message description
Z V0-VF Send or request items: Spot temperatures
Z AP Send or request items: Average product temperature
Z AG Send or request items: Average gas temperature
Z P1, P3
Send or request items: Pressure from transmitter 1 (tank
bottom) and transmitter 3 (top of tank)
Z DQ Send or request items: Measured density
Z RD Send or request items: Radar signal strength amplitude
Z RS Send or request items: Transmitter reset
Z RU Send or request items: Radar ullage level
Z RX Send or request items: Relay status
Z LD Send or request items: Level dimension
Z TD Send or request items: Temperature dimension
Z PI Send or request items: Pressure dimension
Z DI Send or request items: Density dimension