Rosemount 2410 Tank Hub
1.5 Advanced information
1.5.1 Type of Request (TOR)
The Enraf host system can request the following data from the tank hub:
Table 1-3. Data Requests
Table 1-4. Operational Requests
Table 1-5. Testing Operation Requests
TOR Message description
A Send level alarm status
B Send level alarm status and level
C Send level alarm status and temperature
D Send level alarm status, level and temperature
E Send stored level alarm status and level
(1)
1. The tank hub sends the type of level (water or product depending on received operational requests).
F Send stored level alarm status, level and temperature
(1)
L Send water alarm status and signed level
(2)
2. 0.1 mm resolution.
M Send water alarm status and signed level
(2)
TOR Message description
S Store level alarm, level and temperature
U Unlock
(1)
1. No action done.
W Switch to Water Level in B, D and L-record
(2)
2. Only switched if bit is set in MiscCtrl holding register.
Q Quit Water Level
TOR Message description
X Send identification record
(1)