EasyManua.ls Logo

Emerson Rosemount 2410 - Miscellaneous Control Register

Emerson Rosemount 2410
30 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
25
Manual Supplement
00809-0400-2410, Rev AA
Rosemount 2410 Tank Hub
March 2016
Rosemount 2410 Tank Hub
1.5.3 Configuration switches
The Enraf communication board is equipped with configuration switches that can be used
to change settings such as baud rate and bus gain. Figure 1-6 shows where the switches are
located on the communication board.
Figure 1-6. Enraf Communication Board Switches
Change baud rate
The tank hub is pre-configured with baud rate 1200. To change the baud rate set the
switches SW9 and SW10 according to Tab le 1- 7.
Table 1-7. Baude Rate Configuration Switch S3
SW9 SW10 Baud rate
OFF (Open) OFF (Open) 2400 or externally selected
OFF (Open) ON (Closed) 1200 (default)
ON (Closed) OFF (Open) 4800
(1)
1. Not used for Enraf emulation.
ON (Closed) ON (Closed) 4800
(1)
Baud rate
switch S3
Enraf gain
switch S1
SW1
SW2
SW4
SW3
SW9
SW10
SW10
ON (Closed)
OFF (Open)
SW9