WARNING
CRUSHING HAZARD
Do not remove flange stabilizers.
Attempting to do so may allow the meter to roll, resulting in serious injury or
equipment damage.
Figure 1-1: Flange stabilizers
A. Flange stabilizers
CAUTION
ESCAPING FLUIDS HAZARD
The purchaser of the meter is responsible for the selection of Emerson
components/seals and materials compatible with the chemical properties of the
measurement fluid.
Failure to select suitable meter components/seals may cause escaping fluids,
resulting in injury to personnel or equipment damage.
1.2  Field hydrostatic pressure testing
procedures
The Rosemount 3814 Liquid Ultrasonic Flow Meter can be hydro-tested without
any special preparations. The transducers are not exposed to the process
pressure and can remain installed in the meter.
Routine Maintenance Maintenance and Troubleshooting Manual
January2023 00809-0100-3814
6 Emerson.com/Rosemount