Product Data Sheet
00813-0100-4530, Rev DA
December 2010
23
Rosemount 5300 Series
Process Temperature
(2)
Standard (Std) tank connection (Operating Temperature and Pressure code S):
Final rating depends on flange and O-ring selection. The table on page 26 gives the temperature
ranges for standard tank seals with different O-ring materials.
High Temperature and High Pressure (HTHP) tank connection
(Operating Temperature and Pressure code H):
High Pressure (HP) tank connection (Operating Temperature and Pressure code P):
Pressure
psig (bar)
Temperature
°F (°C)
PTFE covered
probe and flange
(model code 7)
Max. Rating, Standard Connections
580 (40)
232 (16)
-14 (-1)
-40 (-40)
302 (150)
Max. Rating, HTHP Connections
5000 (345)
1000 (69)
752 (400)
2940 (203)
-14 (-1)
100 (38)
-76 (-60)
0
400 (204)
600 (316)
200 (93)
Temp.
°F (°C)
Pressure
psig (bar)
Max. Rating, HP Connections
Pressure
psig (bar)
Temperature
°F (°C)
5000 (345)
3524 (243)
3000 (206)
1000 (69)
-14 (-1)
-76 (-60)
0 100 (38)
200 (93)
392 (200)