Product Data Sheet
00813-0100-4530, Rev DA
December 2010
Rosemount 5300 Series
26
High Pressure Steam Applications
Considerations Saturated steam under high
pressure can influence radar
level transmitter measurements.
Rosemount 5301 with Dynamic
Vapor Compensation (DVC) will
automatically compensate for
this and maintain the level
accuracy.
Considerations for DVC:
A Single lead rigid HTHP
probe with a reference
reflector for vapor
compensation must be used
(probe type 4U, 4V)
Mount in a 2, 3, or 4-in
bypass chamber with
flanges appropriately sized
for the pressure and
temperature of the
application
Use a centering disk to
keep the probe centered in
the chamber see “Chamber
/ Pipe Installations” on
page 34
Probes up to 13.1 ft (4 m) in
length are supported
Minimum measuring range is 12 in. (300 mm)
DVC requires a minimum distance from the flange to the surface level in order to measure the
change in the vapor dielectric constant. If the level rises within this area, the unit switches over to
static compensation, using the last known vapor dielectric constant
For more information, refer to the High Pressure Steam Applications Technical Note (Document No.
00840-0100-4530)
(1) Reverse polarity protection.
(2) Final rating may be lower depending on flange and O-ring selection, See “Tank Connection and Probe” on page 31.
Level: 100%
Level: 0%
Minimum distance for dynamic
compensation up to level 100%:
17.3 in. (440 mm) for probes <6 ft. (2 m),
28 in. (710 mm) for probes >6 ft (2 m)
Minimum measuring range:
12 in. (300 mm)
If a spool piece is
used, it is
important that the
reference reflector
is not positioned
where the spool
piece connects to
the chamber.
TABLE 4. Temperature ranges for standard tank seals with different O-ring materials
Tank seal with different
O-ring material
Min. Temperature
°F (°C) in air
Max. Temperature
°F (°C) in air
Viton
®
5 (-15) 302 (150)
Ethylene Propylene (EPDM) -40 (-40) 266 (130)
Kalrez
®
6375 14 (-10) 302 (150)
Buna-N -31 (-35) 230 (110)
NOTE!
Always check the chemical compatibility of the
o-ring material with your application
TABLE 5. 316L SST: conditions used for flange strength calculations
Bolting material Gasket Flange material Hub material
Standard/HTHP HP/HTHP/C
ASME /
ANSI
Stainless steel SA193
B8M C1.2
Soft (1a) with min.
thickness 1.6 mm.
Spiral wound gasket with
nonmetallic filler (1b)
Stainless steel A182
Gr. F316L and
EN 10222-5-1.4404.
Stainless steel A479M
316L, and
EN 10272-1.4404.
EN, JIS
EN 1515-1/-2 group
13E0, A4-70.
Soft (EN 1514-1) with
min. thickness 1.6 mm.
Spiral wound gasket with
nonmetallic filler
(EN 1514-2)

Related product manuals