September 2016
16
Quick Start Guide
7.0 Product certifications
7.1 Approved manufacturing locations
Emerson Process Management Flow Technologies Company, Ltd - Nanjing,
Jiangsu Province, P.R. China
7.2 Flameproof enclosure Ex d protection type in accordance
with IEC 60079-1, EN 60079-1
Transmitters with Flameproof enclosure type protection shall only be opened
when power is removed.
Closing of entries in the device must be carried out using the appropriate Ex d
cable gland or blanking plug. Unless otherwise marked on housing, the
standard conduit entry thread forms are 1/2-14 NPT.
Type n protection type in accordance with IEC 60079-15, EN60079-15
Closing of entries in the device must be carried out using the appropriate Ex e or
Ex n cable gland and metal blanking plug or any appropriate ATEX or IECEx
approved cable gland and blanking plug with IP66 rating certified by an EU
approved certification body.
7.3 European Directive Information
The CE Declaration of Conformity for all applicable European directives for this
product can be found on our website at EmersonProcess.com/Rosemount. A
hard copy may be obtained by contacting our local sales office.
7.4 ATEX Directive
Emerson Process Management complies with the ATEX Directive.
7.5 European Pressure Equipment Directive (PED)
Rosemount 8600D Vortex Flowmeter Line Size 40 mm to
200 mm
Certificate Number 4741-2014-CE-HOU-DNV
0575
Module H Conformity Assessment
Mandatory CE-marking for flowmeters in accordance with Article 15 of the PED
can be found on the flowtube body.
Flowmeter categories I – III use module H for conformity assessment procedures.
Rosemount 8600D Vortex Flowmeter Line Size 25 mm
Sound Engineering Practice (SEP)
Flowmeters that are SEP are outside the scope of PED and cannot be marked for
compliance with PED.