EasyManua.ls Logo

Emerson Rosemount 8600 Series - Page 18

Emerson Rosemount 8600 Series
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
September 2016
18
Quick Start Guide
Type 'n' certification
IEC 60079-0: 2011 Edition: 6.0
IEC 60079-11: 2011-06 Edition: 6.0
IEC 60079-15: 2010 Edition: 4
N7 Certification No. IECEx BAS 12.0054X
Ex nA ic IIC T5 Gc (-40 °C Ta +70 °C)
Maximum Working Voltage = 42Vdc
Special Conditions for Safe Use (X):
1. When fitted with the 90V transient suppressors, the equipment is not capable of
passing the 500V insulation test. This must be taken into account upon installation.
2. When the equipment is installed, particular precautions must be taken to ensure,
taking into account the effect of process fluid temperature, that the ambient
temperature of the electrical housing of the equipment meets the marked protection
type temperature range.
Flameproof certification
IEC 60079-0: 2007 Edition: 5
IEC 60079-1: 2007-04 Edition: 6
IEC 60079-11: 2011 Edition: 6
IEC 60079-26: 2006 Edition: 2
E7 Certification No. IECEx DEK 11.0022X
Integral Transmitter marked:
Ex d [ia] IIC T6 Ga/Gb
Remote Transmitter marked:
Ex d [ia Ga] IIC T6 Gb
Remote Sensor marked:
Ex ia IIC T6 Ga
Ambient temperature range: -50 °C Ta 70 °C
Power Supply: 42 Vdc Max.
Transmitter Um=250 V
Remote mounted sensor: in type of protection Ex ia IIC, only to be connected to the
associated Model 8600D Vortex Flowmeter electronics.
The maximum length of the interconnecting cable is 152 m (500 ft).
Special Conditions for Safe Use (X):
1. For information regarding the dimensions of the flameproof joints, the manufacturer
shall be contacted.
2. The Flowmeter is provided with special fasteners of property class A2-70 or A4-70.
3. Units marked with “Warning: Electrostatic Charging Hazard” may use non- conductive
paint thicker than 0.2 mm. Precautions shall be taken to avoid ignition due to
electrostatic charge of the enclosure.
4. When the equipment is installed, precautions must be taken to ensure, taken into
account the effect of the process fluid temperature, that the ambient temperature of
the electrical parts of the equipment lies between -50 °C and +70 °C.