Electronics verification
Table C-1. Unit Conversions
r=operating density
* Special Units Conversion Factor
C.3 Examples
The following examples illustrate the flowrate calculations that may be necessary for your
application. There are water, saturated steam, and natural gas applications represented in the
examples. The first set of three examples is in English units. The second set of three examples is
in SI units.
C.3.1 English units
Example 1 (English units)
Fluid = Water URV= 500 gpm
Line size = 3 in. LRV= 0 gpm
Line pressure= 100 psig C
2
= 1.66667E-02 (from
Table C-1 on page C-125)
Vortex Frequency = 75 Hz
C
x
Units (act) Conversion Factor
C
1
gal/s 1.00000E+00
C
2
gal/m 1.66667E-02
C
3
gal/h 2.77778E-04
C
4
Impgal/s 1.20095E+00
C
5
Impgal/m 2.00158E-02
C
6
Impgal/h 3.33597E-04
C
7
L/s 2.64172E-01
C
8
L/m 4.40287E-03
C
9
L/h 7.33811E-05
C
10
CuMtr/m 4.40287E-00
C
11
CuMtr/h 7.33811E-02
C
12
CuFt/m 1.24675E-01
C
13
CuFt/h 2.07792E-03
C
14
bbl/h 1.16667E-02
C
15
kg/s C
10
*60/
C
16
kg/h C
11
/
C
17
lb/h C
13
/
C
18
shTon/h C
17
2000
C
19
mTon/h C
16
1000
C
20
SPECIAL C
*