August 2015
4
Quick Start Guide
Note
If the Rosemount 8732EM is mounted separately from the sensor, it may not be subject to
limitations that might apply to the sensor.
Rotate integral mount transmitter housing
The transmitter housing can be rotated on the sensor in 90-degree increments by
removing the four mounting screws on the bottom of the housing. Do not rotate
the housing more than 180 degrees in any one direction. Prior to tightening, be
sure the mating surfaces are clean, the O-ring is seated in the groove, and there is
no gap between the housing and the sensor.
Figure 1. Rosemount 8732EM Dimensional Drawing
Note
Conduit entries are 1/2- in. NPT or M20 connections. If an alternate thread connection is
required, thread adapters must be used.
1.3 Electrical considerations
Before making any electrical connections to the Rosemount 8732EM, consider
national, local, and plant electrical installation requirements. Be sure to have the
proper power supply, conduit, and other accessories necessary to comply with
these standards.
Both remotely and integrally mounted Rosemount 8732EM transmitters require
external power, so there must be access to a suitable power source.