EasyManua.ls Logo

Emerson Rosemount 8700M - IEC EX & ATEX Approval Document; Equipment Markings; Required Documentation; Referenced Documentation

Emerson Rosemount 8700M
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Quick Start Guide
45
August 2015
Rosemount 8700M Magnetic Flowmeter Platform
IEC EX & ATEX Approval Document
January 29, 2015,
08732-AP02, Rev AB
1. Equipment Markings – See section VI in the tables on the following pages
a. EC-Type Examination Certificate (ATEX): DEKRA 14ATEX0071_X
b. Certificate of Conformity (IEC Ex): IEC Ex DEK 14.0031X
2. Required Documentation:
a. 08732-2060 Installation Drawing Model 8732EM, 8705M, 8711-M/L ATEX/IEC Ex Hazardous (Ex)
Locations
b. 08732-1504 Installation Drawing, 8732EM Transmitter Wiring
3. Referenced Documentation:
a. 00825-0100-4444.pdf(Hart) & 00825-0400-4444(Modbus), Quick Installation Guide
b. 00809-0100-4444.pdf, Reference Manual
c. 08732-AP01, Approvals Document
4. The Required and Referenced Documents listed above address the following items:
a. Instructions for safety i.e.
i. Putting into service
ii. Use
iii. Assembling and dismantling
iv. Maintenance, overhaul and repair
v. Installation
vi. Adjustment
b. Where necessary, training instructions
c. Details which allow a decision to be made as to whether the equipment can be used safely in the
intended area under the expected operating conditions
d. Electrical parameters, maximum surface temperatures and other limit values
i. Electrical –
1. See document 08732-2060
2.
Rosemount 8732EM Flow Transmitter
Power input
90 - 250VAC, 0.45A, 40VA
12 - 42VDC, 1.2A, 15W
Pulsed circuit
Internally powered (Active): Outputs up to 12VDC, 12.1mA,
73mW Externally powered (Passive): Input up to 28VDC,
100mA, 1W
4-20mA output circuit Internally Powered (Active): Outputs up to 25mA, 24VDC,
600mW Externally Powered (Passive): Input up to 25mA,
30VDC, 750mW
MODBUS Internally Powered (Active): Outputs up to 100mA, 3.3VDC,
100mW
Um
250V
Coil excitation output
500mA, 40V max, 9W max
Rosemount 8705-M and 8711-M/L Flowtube
(1)
Coil excitation input
500mA, 40V max,
20W max
Electrode circuit
5V,200uA,1mW
(1) Provided by the transmitter
e. Special Conditions for Safe Use (X):

Related product manuals