EasyManua.ls Logo

Emerson Rosemount 8700M - Nomenclature Magnetic Flow Tube Model 8705-M and electrical data

Emerson Rosemount 8700M
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
August 2015
48
Quick Start Guide
Rosemount 8700M Magnetic Flowmeter Platform
IEC EX & ATEX Approval Document
January 29, 2015,
08732-AP02, Rev AB
Nomenclature Magnetic Flow Tube Model 8705-M and electrical data
8705
S A 005 M4 K1 G1 L1 B3 J1 SJ V1 SH F090x
I II III IV V VI VII VIII IX X XI XII XIII XIV
Designation Explanation Value Explanation
I Model 8705 Magnetic Flowtube
II Electrode Material Custom See special conditions for safe use
III Electrode Types Custom Seal of electrodes comply with IEC 61010-1
IV Line Size
005
to
360
½” NPS (15 mm)
to
36” NPS (900 mm)
V Electrode Housing *
M0
M1
M2
M3
M4
Category 2 G or 3 G, EPL Gb or Gc
Category 2 G or 3 G, EPL Gb or Gc
Category 1/2 G or 1/3 G, EPL Ga/Gb or Ga/Gc
Category 1/2 G or 1/3 G, EPL Ga/Gb or Ga/Gc
Category 1/2 G or 1/3 G, EPL Ga/Gb or Ga/Gc
VI Safety Approvals
K1 ATEX
II 1/2 G Ex e ia IIC T5…T3 Ga/Gb *
II 2 D Ex tb IIIC T 80 °C…T 200 °C Db
II 2 G Ex e ib IIC T5…T3 Gb **
II 2 D Ex tb IIIC T 80 °C…T 200 °C Db
K7 IECEx
Ex e ia IIC T5…T3 Ga/Gb *
Ex tb IIIC T 80 °C…T 200 °C Db
Ex e ib IIC T5…T3 Gb **
Ex tb IIIC T 80 °C…T 200 °C Db
N1 ATEX
II 1/3 G Ex nA ia IIC T5…T3 Ga/Gc *
line sizes 8”- 36”
II 2 D Ex tb IIIC T 80 °C…T 200 °C Db
II 3 G Ex nA ic IIC T5…T3 Gc *
line sizes 0.5” – 6” /
**
II 2 D Ex tb IIIC T 80 °C…T 200 °C Db
N7 IECEx
Ex nA ia IIC T5…T3 Ga/Gc *
line sizes 8”- 36”
Ex tb IIIC T 80 °C…T 200 °C Db
Ex nA ic IIC T5…T3 Gc *
line sizes 0.5” – 6” /
**
Ex tb IIIC T 80 °C…T 200 °C Db
ND ATEX
II 2 D Ex tb IIIC T 80 °C…T 200 °C Db
NF IECEx Ex tb IIIC T 80 °C…T 200 °C Db
NOTE: * Electrode Housing M2, M3 and M4 only
** Electrode Housing M0 and M1 only
VII
Grounding rings
material
Custom See special conditions for safe use
VIII
Lining protector
material
Custom See special conditions for safe use
IX
Mounting
Configuration
B3 Integral Mount with Model 8732EM
X
Optional conduit
entries
J1 CM20, M20 female
XI
Remote Junction Box
(RJB) material
--
SJ
Aluminum, Standard Paint
316 Stainless Steel
XII Special paint options Vx Special Paint Systems ***
XIII
Wrapper (housing)
material
--
SH
Carbon Steel (w. Aluminum RJB), Standard Paint
316 Stainless Steel (w. Stainless Steel RJB)
XIV Specials F090x Special Paint Systems ***
NOTE: *** Subject to special conditions for safe use.