9.3 List of Parameters and Registers - Sorted by Tag Name
Tag Name Address
Data
Type
Client
Access
Description
Modicon Daniel
Service.Measurement.Compensation.ToffEn-
able1
3401 3401 Word R/W
enable temperature zero compensation
of comp1
Service.Measurement.Compensation.ToffEn-
able2
3402 3402 Word R/W
enable temperature zero compensation
of comp2
Service.Measurement.Compensation.ToffEn-
able3
3403 3403 Word R/W
enable temperature zero compensation
of comp3
Service.Measurement.Compensation.ToffEn-
able4
3404 3404 Word R/W
enable temperature zero compensation
of comp4
Service.Measurement.Compensation.ToffEn-
able5
3405 3405 Word R/W
enable temperature zero compensation
of comp5
Service.Measurement.Compensation.Toff-
SensorAssign1
3406 3406 Word R/W
assign temp-sensor of zero comp1
(0=None 1=DSP_T1 2=DSP_T2 etc.
Service.Measurement.Compensation.Toff-
SensorAssign2
3407 3407 Word R/W
assign temp-sensor of zero comp2
(0=None 1=DSP_T1 2=DSP_T2 etc.
Service.Measurement.Compensation.Toff-
SensorAssign3
3408 3408 Word R/W
assign temp-sensor of zero comp3
(0=None 1=DSP_T1 2=DSP_T2 etc.
Service.Measurement.Compensation.Toff-
SensorAssign4
3409 3409 Word R/W
assign temp-sensor of zero comp4
(0=None 1=DSP_T1 2=DSP_T2 etc.
Service.Measurement.Compensation.Toff-
SensorAssign5
3410 3410 Word R/W
assign temp-sensor of zero comp5
(0=None 1=DSP_T1 2=DSP_T2 etc.
Service.Measurement.Compensation.Toff-
Temperature1
6521…
6522
9261 Float RO
temperature for zero compensation of
comp1
Service.Measurement.Compensation.Toff-
Temperature2
6523…
6524
9262 Float RO
temperature for zero compensation of
comp2
Service.Measurement.Compensation.Toff-
Temperature3
6525…
6526
9263 Float RO
temperature for zero compensation of
comp3
Service.Measurement.Compensation.Toff-
Temperature4
6527…
6528
9264 Float RO
temperature for zero compensation of
comp4
Service.Measurement.Compensation.Toff-
Temperature5
6529…
6530
9265 Float RO
temperature for zero compensation of
comp5
Service.Measurement.Lin.CalcResults1
3571…
3574
3571…
3574
Word RO
LinCalc results (P1..P4) comp1 (0=No-
Coeff 1=Good 2=Busy ..)
Service.Measurement.Lin.CalcResults2
3575…
3578
3575…
3578
Word R/W
LinCalc results (P1..P4) comp2 (0=No-
Coeff 1=Good 2=Busy ..)
Service.Measurement.Lin.CalcResults3
3579…
3582
3579…
3582
Word R/W
LinCalc results (P1..P4) comp3 (0=No-
Coeff 1=Good 2=Busy ..)
Service.Measurement.Lin.CalcResults4
3583…
3586
3583…
3586
Word R/W
LinCalc results (P1..P4) comp4 (0=No-
Coeff 1=Good 2=Busy ..)
Service.Measurement.Lin.CalcResults5
3587…
3590
3587…
3590
Word R/W
LinCalc results (P1..P4) comp5 (0=No-
Coeff 1=Good 2=Busy ..)
Service.Measurement.Lin.CalcSets1 3526 3526 Word R/W
LinFct PolySets (0=All 1=P1 2=P2
3=P3 4=P4) comp1
Service.Measurement.Lin.CalcSets2 3527 3527 Word R/W
LinFct PolySets (0=All 1=P1 2=P2
3=P3 4=P4) comp2
Service.Measurement.Lin.CalcSets3 3528 3528 Word R/W
LinFct PolySets (0=All 1=P1 2=P2
3=P3 4=P4) comp3