The ERTune™ Program: Basic Features
10. Click the Next > button. The PID Download window opens.
The ER5000 software includes PIDs specically tuned for
most TESCOM™ regulators, as well as default PIDs that are
used if Other or None has been selected.
11. Click the Yes button to download the PID settings tuned for
the regulator or the No button to use the factory settings.
12. The ERTune™ program opens.
IMPORTANT
!
IMPORTANT
!
If the regulator you selected in Step 9 is a
diaphragm sensed regulator, the Regulator Diaphragm Protection
window opens. You can congure the ER5000 for diaphragm protection.
Non-venting regulators, which do not feature a regulator
vent to exhaust excess system pressure, pose a particular
challenge in closed loop applications when the downstream
ow is blocked.
Regulator Diaphragm Protection is designed for applications
that use a non-venting regulator in a system that does not
have continuous ow. It is most benecial for this type of
application when the regulator is a metal diaphragm sensed
regulator. For more information on this feature, refer to
A Note Concerning Non-Venting Regulators in Closed Loop
Applications.
(continued next page)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Tescom ER5000 Series and is the answer not in the manual?

Emerson Tescom ER5000 Series Specifications

General IconGeneral
BrandEmerson
ModelTescom ER5000 Series
CategoryController
LanguageEnglish

Related product manuals