Safety 
information
Product 
information
Mechanical 
installation
Electrical 
installation
Getting 
started
Basic 
parameters
Running the 
motor
Optimization NV Media Card
Advanced 
parameters
Diagnostics UL Listing
Unidrive M100 / M101 Control User Guide             29
Issue Number: 1            
Figure 6-6 Pr 00.005 = AV.Pr (50 Hz)
Figure 6-7 Pr 00.005 = AV.Pr (60 Hz)
Figure 6-8 Pr 00.005 = AI.Pr (50 Hz)
Figure 6-9 Pr 00.005 = AI.Pr (60 Hz)
* Refer to section 10.2 Menu 1: Frequency reference on page 52.
1
2
4
9
0 V
10k
Voltage speed
reference input (AI 1)
Reference select
Reference select
10
11
12
13
Drive enable
Run forward
+ 10 V output
+ 24 V output
Terminal 10 Terminal 13 Reference selected
0 0 Analog reference 1*
0 1 Preset speed 2*
1 0 Preset speed 3*
1 1 Preset speed 4*
1
2
4
9
0 V
10k
Voltage speed
reference input (AI 1)
Reference select
Reference select
10
11
12
13
Not stop
Run
+ 10 V output
+ 24 V output
Terminal 10 Terminal 13 Reference selected
0 0 Analog reference 1*
0 1 Preset speed 2*
1 0 Preset speed 3*
1 1 Preset speed 4*
1
2
4
9
0 V
Current speed
reference input (AI 1)
Reference select
Reference select
10
11
12
13
Drive enable
Run forward
+ 10 V output
+ 24 V output
Current speed
reference input
Terminal 10 Terminal 13 Reference selected
0 0 Analog reference 1*
0 1 Preset speed 2*
1 0 Preset speed 3*
1 1 Preset speed 4*
1
2
4
9
0 V
Current speed
reference input (AI 1)
Reference select
Reference select
10
11
12
13
Not stop
Run
+ 10 V output
+ 24 V output
Current speed
reference input
Terminal 10 Terminal 13 Reference selected
0 0 Analog reference 1*
0 1 Preset speed 2*
1 0 Preset speed 3*
1 1 Preset speed 4*