Safety 
information
Product 
information
Mechanical 
installation
Electrical 
installation
Getting 
started
Basic 
parameters
Running the 
motor
Optimization
NV Media 
Card
Advanced 
parameters
Diagnostics UL Listing
Unidrive M100 / M101 Control User Guide             43
Issue Number: 1            
Displays the type/mode of the data block selected with Pr 11.037.
Displays the version number of the file selected in Pr 11.037. 
9.4      NV Media Card trips
After an attempt to read, write or erase data from a NV Media Card a trip 
is initiated if there has been a problem with the command. 
See Chapter 11 Diagnostics on page 80 for more information on NV 
Media Card trips.
9.5      Data block header information
Each data block stored on a NV Media Card has header information 
detailing the following:
• NV Media Card File Number (11.037)
• NV Media Card File Type (11.038)
• NV Media Card File Version (11.039)
The header information for each data block which has been used can be 
viewed in Pr 11.038 to Pr 11.039 by increasing or decreasing the data 
block number set in Pr 11.037. If there is no data on the card Pr 11.037 
can only have a value of 0.
11.038 NV Media Card File Type
RO Txt ND NC PT
Ú
0 to 1
Ö
0
Pr 11.038 String Type / mode
0 None No file selected
1 Open-loop Open-Loop mode parameter file
11.039 NV Media Card File Version
RO Num ND NC PT
Ú
0 to 9999
Ö
0
11.042 {00.030} Parameter Cloning
RW Txt NC US
Ú
NonE (0), rEAd (1), Prog 
(2), Auto (3), 
boot (4)
Ö
0