SI-Ethernet User Guide 31
Issue: 1
Safety
information
Introduction
Mechanical
installation
Electrical
installation
Getting started Parameters
Key features
and Protocols
PC Applications Security Diagnostics
Glossary of
terms
Index
5.10.6 Menu 15 - Modbus
Table 5.10 Menu 15 parameters
11.052
Rx2 Late
Synchronization
Frame Event
No Event (0),
Event (1),
Event 1 (2),
Event 2 (3),
Event 3 (4)
No Event
(0)
RW Txt US
11.060
Rx3 Late
Synchronization
Frame Action
Trip (1),
Do not use (2),
Use (3)
Trip (1) RW Txt US
11.061
Rx3 Late
Synchronization
Frame Destination
This slot (0),
Slot 1 (1).
Slot 2 (2),
Slot 3 (3),
Slot 4 (4)
This slot
(0)
RW Txt US
11.062
Rx3 Late
Synchronization
Frame Event
No Event (0),
Event (1),
Event 1 (2),
Event 2 (3),
Event 3 (4)
No Event
(0)
RW Txt US
Parameter Range Default Type
Parameter Range Default Type
15.001
Enable Off (0) or On (1) On (1) RW Bit US
15.002 Reset Off (0) or On (1) Off (0) RW Bit NC
15.
003
Default Off (0) or On (1) Off (0) RW Bit NC
15
.
004
Modbus
Configuration Error
No error (0),
Port in use (1),
Timeout event (2),
Num Connections (3)
RO Txt ND
15
.
005
Modbus Listening
Port
0 to 65535 502 RW Num US
15
.
006
Maximum
Connections
0 to 4 2 RW Num US
15
.
007
Maximum Priority
Connections
0 to 4 0 RW Num US
15
.
008
Maximum
Connections
Per Client
1 to 4 2 RW Num US
15
.
009
Modbus Timeout 1 to 10000 ms 100 ms RW Num US
15
.010
Modbus Timeout
Action
Trip (0),
No action (1)
No action
(1)
RW Txt US