56 SI-Ethernet User Guide
Issue: 1
Defines, in milliseconds, the rate at which Tx1 Link will be transmitted. A value of zero
disables the transmission of data.
S.10.016 Tx1 Message Rate
Minimum 0 Maximum 100
Default 0 Units ms
Type 8 Bit User Save Update Rate Read on reset
Display Format None Decimal Places 0
Coding RW, BU
S.10.019 Tx1 Link Status
Minimum -30 Maximum 2
Default 0 Units
Type 8 Bit Volatile Update Rate Write on reset
Display Format None Decimal Places 0
Coding RO, TE
Value Text Description
-30 VLAN disabled
VLAN is required in order to guarantee timing in
synchronous mode but it is disabled
-29 Reserved 29 Reserved for future use
-28 Reserved 28 Reserved for future use
-27 Reserved 27 Reserved for future use
-26 Reserved 26 Reserved for future use
-25 Reserved 25 Reserved for future use
-24 Reserved 24 Reserved for future use
-23 Reserved 23 Reserved for future use
-22 Invalid DST IP Destination IP address is invalid
-21 SYNC unsupported
Sync link does not support mappings to other option
parameters
-20 MEC offset Incorrect MEC offset
-19 Invalid tx rate Tx rate must be a factor of 1 second
-18 Too many mapping
The number of mapping items exceeds the range
supported
-17 Link busy The link specified is busy
-16 Invalid profile The profile is invalid
-15 Invalid mapping The mapped parameter does not exist
-14 Read only param The mapped parameter is read only
-13 Msg mismatch Link number and direction do not match
-12 Msg too long Resulting message is too long
-11 Attrib NA Attribute not available