64 SI-Ethernet User Guide
Issue: 1
This parameter reports the link’s status if it has been loaded. A Reset (S.10.002) is
required to load any changes.
Used to select Rx1 as a standard or synchronous cyclic link.
This parameter is used to set the link number (1 to 255) for the Rx1 link.
This parameter sets the destination parameter for the Rx1 link.
-3 Invalid args Link number / argument zero or invalid
-2 Too many links Maximum number of links has been reached
-1 Out of memory Failed to allocate memory
0 OK Configuration of link successful
1 Not running Ok, not running
2 OK sync Configuration of synchronous link successful
S.10.040 Rx1 Link Profile
Minimum 0 Maximum 1
Default 0 Units
Type 8 Bit User Save Update Rate Read on reset
Display Format None Decimal Places 0
Coding RW, TE
Value Text Description
0
Std Standard link
1
Sync Synchronized link
S.10.041 Rx1 Link Number
Minimum 0 Maximum 255
Default 0 Units
Type 8 Bit User Save Update Rate Read on reset
Display Format None Decimal Places 0
Coding RW, BU
S.10.042 Rx1 Destination Parameter
Minimum
0
(Display: 0.00.000)
Maximum
499999
(Display: 4.99.999)
Default
0
(Display: 0.00.000)
Units
Type 32 Bit User Save Update Rate Read on reset
Display Format Slot Menu Param Decimal Places 0
Coding RW, BU
Value Text Description