88 SI-Ethernet User Guide
Issue: 1
Defines the action when no message is received within the time period specified in
Modbus Timeout (S.15.009).
Defines the destination slot to trigger the event (defined by Modbus Timeout Event Type
(S.15.012)) when a timeout occurs.
Value Text Description
0 Trip Trip drive and raise error
1 No action
No action
S.15.011 Modbus Timeout Event Destination
Minimum 0 Maximum 4
Default 0 Units
Type 8 Bit User Save Update Rate
Module reset, Modbus
interface reset or Modbus
interface enable
Display Format None Decimal Places 0
Coding RW, TE, BU
Value Text Description
0 This slot Trigger event in this slot
1 Slot 1 Trigger event in slot 1
2 Slot 2 Trigger event in slot 2
3 Slot 3 Trigger event in slot 3
4Slot 4
Trigger event in slot 4
This feature is not yet implemented.
S.15.012 Modbus Timeout Event Type
Minimum 0 Maximum 5
Default 0 Units
Type 8 Bit User Save Update Rate
Module reset, Modbus
interface reset or Modbus
interface enable
Display Format None Decimal Places 0
Coding RW, TE, BU
NOTE