4. Once time is set, press the button once; the temperature value
will start ashing. Use + or – to set the temperature.
5. Once temperature is set, press the button once; „P2“ will appear
on the display and the time value will start ashing. Repeat steps 3
and 4 until all six programmes are set.
6. After setting all six programmes to the values of choice, press the
button to conrm or wait 60 seconds for automatic conrmation.
Using the Copy Function
The thermostat is equipped with a copy function which allows copying an
edited programme to another day. You therefore do not have to repeatedly
enter the same programme for the next day. This function only works
when programming individual days.
1. First, set and save a programme for at least one day; see Pro-
gramme Settings.
2. If the thermostat is set to day mode and the slider is on PROG,
press the C button.
3. „MO“ will appear on the display; at this point, use + or – to select
which day‘s settings you wish to copy to another day.
4. Press the button; „TU“ will start ashing on the display. Use +
or – to choose the day you wish to copy the selected settings into.
5. Press the C button to conrm your day selection; „SAVE“ will appear
on the display. To choose additional days, repeat steps 3 and 4.
6. After copying the original setting to the days of choice, conrm
by pressing the
button or wait 60 seconds for automatic con-
rmation.
Temporary Mode
1. Move the slider to AUTO.
2. Use + or – to set the temperature of choice; a hand icon will appear
on the display.
3. Press the
button to conrm or wait 15 seconds for automatic
conrmation.
This temperature setting will apply until the next preset programme
begins or until you press the
button again to cancel temporary mode.
Manual Temperature Setting Mode (MAN)
1. Move the slider to MAN.
2. Press + or – to adjust temperature.
In this mode, the thermostat always maintains the manually set temper-
ature and preset programmes are not active. You can cancel the mode
by moving the slider to another position.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emos P5616OT and is the answer not in the manual?

Emos P5616OT Specifications

General IconGeneral
Frequency868 MHz
InterfaceAC
Child lockYes
Proper useRoom
Control typeButtons
Product colorWhite
Memory functionNo
Units of measurement°C
Temperature increment0.5 °C
Temperature setpoint range5 - 35 °C
Battery typeAA
Power sourceAC/Battery
Battery voltage1.5 V
Operating voltage230 V
Maximum switching current10 A
Number of batteries supported2
Weight and Dimensions IconWeight and Dimensions
Depth26 mm
Width86 mm
Receiver dimensions (WxDxH)86 x 26 x 86 mm
Bridge dimensions (W x D x H)126 x 26 x 84 mm